Total System Rejuvenation 60-Point Checklist

Condenser

  • Check to make sure the condenser is level.
  • Remove dirt, debris, and leaves from inside the condenser.
  • Clean electrical components with compressed air or nitrogen.
  • Verify that drainage holes in the bottom of the condenser are clear.
  • Check for damaged fins; straighten if necessary.
  • Clean condenser coils and exterior of unit.
  • Check condenser fan mounting bracket or wires.
  • Check and record condenser fan amp draw.
  • Check the condenser fan motor for bearing wear.
  • Lubricate the motor is applicable.
  • Check the balance of condenser fan blade.
  • Check and record coil temperature differential.
  • Check refrigerant piping for kinks or bends.
  • Check suction line insulation.
  • Tighten and secure all electrical connections.
  • Check for frayed, worn, or brittle wiring.
  • Check for proper voltage; record.
  • Check the outdoor electrical disconnect.
  • Check fuse holders and verify correct fuse sizes.
  • Verify capacitor microfarad rating.
  • Check crankcase heater operation.
  • Check contactor contacts and operation.
  • Check electrical relays.
  • Check high and low-pressure controls.
  • Check and record superheat and sub-cooling.
  • Check compressor terminals.
  • Check and record compressor amp draw.
  • Check for high temperature differential across refrigeration components.
  • Check and record operating temperatures and pressures.
  • Check for adequate refrigerant change.
  • Check for refrigerant leaks.
  • Check to make sure refrigerant piping is secure and not vibrating.
  • Check for and replace missing screws, bolts, and hardware.

Evaporator

  • Check and clean the evaporator coil.
  • Check the coil for air restriction.
  • Check the TXV for proper location and contact with the suction line.
  • Check and secure suction line insulation.
  • Check capillary tubing for kinks.
  • Check and clean the condensate pump, including the safety switch.

Furnace, Air Handler, Controls

  • Check and clean the blower assembly.
  • Check the air filter; clean or replace as necessary.
  • Clean the inside compartments of the air handler.
  • Check the blower motor; lubricate is applicable.
  • Check and record blower motor amp draw.
  • Check blower belt and tension, if applicable.
  • Check fan center and cooling relay.
  • Clean the exterior of the unit.
  • Tighten and secure unit electrical connections.
  • Check for frayed, brittle, or worn wiring.
  • Check and record temperature drop across the evaporator coil.
  • Check for and replace missing screws, bolts, and hardware.
  • Check thermostat electrical connections.
  • Make sure the thermostat is level.
  • Check thermostat accuracy.

Ductwork

  • Verify that all registers are open.
  • Check the system’s external static pressure.
  • Check for proper airflow.
  • Verify proper duct sizes.
  • Check ductwork for air leakage.
  • Check for any missing or loose insulation.

All this for just $189 $79 LIMITED TIME INTERNET SPECIAL - CALL NOW!!

Schedule Your Total System Rejuvenation Now!

Call Now! 813-643-0609

(Be sure to mention Internet Special ID 99-42-57!)

Click here to learn more about the Total System Rejuvenation